Fort Worth adopted the 2021 International Fire Code with local amendments by Ordinance 25388-03-2022. Its fire lane rules keep a building with high-piled storage within 150 feet of a fire lane even when it is sprinklered, lanes must carry 85,000 pounds, and private hydrants are painted red and maintained by the property owner.
What Fort Worth’s fire rules add
- The codeThe 2021 International Fire Code with Fort Worth amendments, Ordinance 25388-03-2022, enforced by the Bureau of Fire Prevention.
- Fire lanesA fire lane must come within 150 feet of all portions of a building. Sprinklered buildings may stretch that to 300 feet, but not buildings with high-piled combustible storage or Group H hazardous occupancies.
- Lane strengthFire lanes are at least 20 feet wide, carry at least 85,000 pounds on asphalt or concrete and keep an inside turning radius of at least 25 feet.
- Private waterPrivate hydrants are painted red and maintained by the property owner, and private underground fire mains need a fire department construction permit and a State Fire Marshal-licensed underground contractor.
- During constructionNew construction over 20,000 square feet needs a site safety plan, and a fire watch applies to noncombustible buildings over 40 feet tall and 50,000 square feet per story until fire protection is working.
The coverage parts are on my warehouse insurance page; tornado, hail and Trinity flood questions for Fort Worth buildings are on the Fort Worth commercial property page. This page covers the warehouse itself, as of November 2026.
Building a tilt-wall: the months before the sprinklers work
Fort Worth’s fire lane guide gives tilt-wall and noncombustible construction a break on timing: construction access roads must meet fire lane requirements except surface and marking, but fire lanes and hydrants must be complete and approved before combustible materials, including roofing materials, are stored on site. For a builder’s risk underwriter, that sequence is the whole question.
- Panels are not the risk. Cast concrete walls rarely burn. Roofing, insulation, pallets of tenant fixtures and the wood forms are what a construction fire feeds on.
- Show the dates. When hydrants were accepted, when the sprinklers were put in service and when the fire watch ended. A gap between roofing delivery and live sprinklers is where premiums and exclusions come from.
- Wind on tall panels. Braced panels before the roof ties them together are exposed to the spring storms North Texas gets; the builder’s risk form and deductible should say how that is handled.
The policy for the building under way is builder’s risk; the permanent property policy should start the day the builder’s risk ends, with no gap at the certificate of occupancy.
Private hydrants, mains and the sprinkler’s water supply
On a large industrial lot, the sprinkler system depends on pipe the city does not own. Fort Worth puts that pipe on the owner: private hydrants are red and maintained by the property owner, and new or replaced fire department connections need locking caps. Underwriters read that as a maintenance question.
- Inspection records for hydrants, the fire pump if there is one, and the main riser, with the latest flow test.
- Impairment procedure: who notifies the insurer and the fire department when a valve is shut for work, and what happens to hot work until it is reopened. Many property forms have impairment conditions; a closed valve that nobody reported can complicate a claim.
- Key box: Fort Worth requires a key box where access is difficult or a fire alarm system is installed, and the operator must hand over new keys when locks change.
Cold rooms, stock values and the income behind them
- Ammonia refrigeration: a cold storage system holding more than 10,000 pounds of anhydrous ammonia falls under OSHA’s process safety management standard. Underwriters ask for the PSM program and the last compliance audit, and the property policy needs equipment breakdown for compressors and condensers.
- Spoilage: product lost when refrigeration fails is a separate coverage with its own triggers, such as breakdown, power loss off premises or contamination. I match it to how long your product holds temperature.
- Valuation: stock you own can be insured at cost or at selling price; for a 3PL, customer goods are a liability question, not a property one.
- Batteries: Fort Worth is on the 2021 code, and the model code’s lithium-ion storage section arrived in 2024. I still list battery stock and charger locations for the underwriter.
Goods you store for others
In Texas the warehouse’s duty is set by Chapter 7 of the Business and Commerce Code: reasonable care over stored goods under Section 7.204, with any limit stated in the receipt or storage agreement, and goods covered by different receipts kept separate under Section 7.207 unless the receipt allows commingling of fungible goods. A warehouse legal liability policy answers that duty. It is worth matching its limit and its valuation to what your receipts promise, not to a round number.
Bonded or high-value freight from air and rail customers can push a single customer’s stock past a standard limit. Tell me the largest value one customer keeps in the building on a peak day. Hauling it is a separate placement (Fort Worth fleet insurance).
Docks, forklifts and contract terms
- Premises: outside drivers on your dock and in your yard are the common liability claim. Written dock rules and a driver waiting area help.
- Additional insureds: landlords and lenders want to be named, and some want primary and noncontributory wording; the certificate has to match the endorsement.
- Indemnity: customer agreements often add hold-harmless language. The liability policy covers some contractual liability, not all of it, so I read the clause before renewal.
- Umbrella: set above general liability, auto and employer’s liability to the highest limit any lease or customer asks for (commercial umbrella).
Workers’ comp for a Fort Worth floor
Texas lets most private employers go without comp, and an employer who does needs to understand what that gives up (is workers’ comp required in Texas). Many warehouse customers require it anyway. Texas class codes, PEO agreements and the mod are covered on my Dallas workers’ comp page, and they apply the same way in Tarrant County.
What to send me
- Each building: year built, wall and roof type, square footage, clear height and the certificate of occupancy date.
- The fire file: high-piled storage plans, sprinkler design, hydrant and fire pump inspections, the latest flow test and your impairment procedure.
- For new construction: the schedule, the site safety plan, and the dates hydrants and sprinklers went into service.
- Cold storage: refrigerant type and quantity, the PSM program if it applies, and alarm and backup power details.
- A statement of values and your receipt or storage terms, the lease and your largest customer contracts.
- Five years of loss runs on every line.
Call or text (877) 711-4545. From outside the U.S. or Canada: +1 (424) 552-4545.
Common questions
Do you have an office in Fort Worth?
No. Alishahi Insurance has one office, in Beverly Hills, California. I am licensed in Texas and work with Fort Worth warehouse owners and operators by phone, text and online.
How close must a fire lane be to a Fort Worth warehouse with high-piled storage?
Within 150 feet of all portions of the building. The 300-foot allowance for sprinklered buildings does not apply when the building has high-piled combustible storage.
Who maintains private fire hydrants on a Fort Worth industrial property?
The property owner. Fort Worth’s requirements say private hydrants are painted red and properly maintained by the owner.
When do fire lanes have to be finished on a new tilt-wall building?
Fort Worth requires fire lanes and fire hydrants to be complete and approved before combustible materials, including roofing materials, are stored on the construction site.
Does a cold storage warehouse need special coverage?
Usually equipment breakdown for the refrigeration system and spoilage coverage for the product, and an ammonia system over 10,000 pounds falls under OSHA’s process safety management standard.
General information about insuring warehouses in Fort Worth as of November 2026, not legal or engineering advice. The Fort Worth Fire Code, its fire lane and hydrant requirements, Texas statutes and OSHA rules change; confirm current requirements with the Bureau of Fire Prevention and counsel. Coverage depends on underwriting and the terms, conditions and exclusions of the policy actually issued.