Builder’s risk covers the building and the materials meant for it while the work is underway. On a San Diego apartment, commercial or custom-home project the underwriting turns on how the site is protected after hours, how water and sprinkler systems are tested, whether people still occupy the building, and what the lender requires. Earthquake and earth movement are separate decisions. I place the insurance; the construction is your contractor’s job.
The City’s construction fire-safety standard
San Diego Fire-Rescue’s Standard A-7, Fire Safety During Construction and Demolition, took effect January 9, 2024 and was revised March 26, 2025. It covers new construction, demolition and significant alterations in the department’s jurisdiction and is based on the 2022 California Fire Code and NFPA 241. The parts an underwriter will recognize:
- Owner’s planThe owner is responsible for a written site safety plan kept on site, covering hot work, combustible waste, flammable liquids and site security, among other items. The owner names a site safety director, who runs a documented daily fire safety inspection; by the third failure to keep those records, the fire code official may issue a stop work order.
- Water firstA fire water supply must be in place before combustible materials arrive, before vertical combustible construction starts and before a standpipe goes in, with the hydrant within 500 feet of the materials. Projects with private fire access roads, on-site hydrants or a standpipe connection schedule a site safety inspection before materials arrive.
- Fire watchA fire watch during nonworking hours is required for new construction more than 40 feet high, for new multistory construction with more than 50,000 square feet per story, or when the fire code official requires it. Monitored temporary fire alarm systems can be proposed instead.
- StorageYard storage of equipment and combustible materials stays at least 30 feet from the structure under construction.
Builder’s risk underwriters ask for much of the same. IRMI commentary describes a six-foot fence locked during nonworking hours as a common condition, along with insurer-approved site surveillance. The fire watch log, the daily inspections and the plan’s security provisions go with my submission, and they answer the theft questions too: the policy is written for building materials and fixtures not yet installed, while contractors’ tools belong on their own equipment coverage.
Testing, sprinklers and water damage
Testing is when new pipes and sprinkler lines first hold water under pressure, and the City’s standard has rules for it. It makes it unlawful to occupy any part of a building that needs sprinklers until the system has been tested and approved, and where sprinkler protection is turned off and on to connect new sections, the control valves must be checked at the end of each work period to confirm protection is back in service.
- Testing and startup. AIA’s 2017 Exhibit A, in its printed form, calls for the builder’s risk to cover building systems damaged during testing and startup. IRMI treats hot testing separately, meaning startup, commissioning, operational or performance testing of machinery and equipment, and says a project with production machinery should require it.
- Water conditions. IRMI lists acceptable water damage mitigation measures and satisfactory water-flow detection devices among the conditions seen in builder’s risk proposals. Expect to show a written water plan: who opens valves, how leaks are found after hours and who responds.
- Separate deductibles. Some insurers apply one deductible to physical damage and separate ones to water damage and hot testing. Compare those lines before you compare prices.
Rain through an open roof, a burst line during a pressure test and a fixture leaking overnight can read differently under each form, so I compare the water wording line by line. What builder’s risk covers and excludes.
Backcountry projects and the County’s 2026 wildfire code
In the unincorporated county, the County of San Diego’s 2026 Wildland-Urban Interface Code took effect April 2, 2026. It joins the County’s amendments to the 2025 California Wildland-Urban Interface Code, the state code that took over Chapter 7A of the Building Code when the 2025 codes took effect on January 1, 2026, with the ordinances of the 12 unincorporated County fire protection districts.
- Where it appliesNew residential, commercial, educational and similar buildings in any fire hazard severity zone, including State Responsibility Area land rated moderate, high or very high.
- Four districts go furtherIn the Alpine, Bonita-Sunnyside, Lakeside and San Miguel fire protection districts, the code treats all State Responsibility Area land as a very high fire hazard severity zone.
- Older buildingsAdditions to and remodels of buildings first built before July 1, 2008 are excepted from the code’s application rule.
Ignition-resistant construction changes the materials list, and the builder’s risk limit has to follow it: a backcountry rebuild is insured for the cost of building to the current code. When no all-risks market will take a site in a very high zone, the California FAIR Plan accepts ground-up residential and commercial construction, but only for fire, lightning and internal explosion, plus vandalism if you buy it. Theft, water damage and everything else then have to be covered some other way.
Renovating a building with people in it
A major renovation of an occupied apartment building, hotel or office building carries two properties at once: the new work and the existing structure around it. The City’s standard keeps the existing building usable: required exits must be maintained during alterations unless a temporary route is approved, and combustible materials may not be stored in exits, stair enclosures or exit corridors serving 30 or more occupants.
- Who insures the existing structure. The AIA exhibit, as drafted, puts all-risks replacement cost insurance on the existing structure on the owner for remodels and additions. ConsensusDocs dropped its requirement to cover existing structures under the builder’s risk in 2023, saying such coverage may not always be feasible. Tell the insurer on the building’s own property policy about the work before it starts, and get its answer in writing.
- Actual cash value. IRMI commentary warns that many builder’s risk policies insure existing structures only at actual cash value, not replacement cost.
- Moving people back in early. Under the AIA exhibit, the owner may not occupy finished portions before substantial completion until the builder’s risk insurer consents in writing.
The permanent side of the building is on apartment building insurance.
Lenders and completed value
Lenders set the floor. Fannie Mae’s multifamily guide tells its lenders that when a property policy excludes coverage during construction, renovation or restoration, builder’s risk must be in place for the work. Its builder’s risk section, written for adding dwelling units to a financed property, asks for coverage from the start of construction to completion at no less than the full completed value, counting all project contracts and materials, with soft costs included on a non-reporting basis: interest during construction, taxes, architect and engineering fees and other overhead tied to delay.
The AIA exhibit names mortgagees as loss payees, and IRMI notes that loan agreements sometimes require the lender to be named as an insured or loss payee. On the contract side, AIA Contract Documents describes the owner as the usual buyer of the project’s property insurance, while ConsensusDocs forms default to the constructor. I send the lender’s insurance letter with the submission so the first quote is the one that closes. Why builder’s risk is often an inland marine policy.
Bluff sites and earthquake
On the coast, the Coastal Commission’s permit can put the hazard squarely on the owner. A December 2023 staff report for an addition and structural remodel of a blufftop home in Solana Beach conditioned the permit on the owners acknowledging erosion and bluff-collapse hazards, assuming the risk of damage from them, waiving claims against the Commission and indemnifying it, with the conditions recorded as a deed restriction. Most of that risk is earth movement, a common builder’s risk exclusion; insurers generally offer earth movement and flood only by endorsement or as separate policies.
Earthquake follows the same pattern. Unless the parties change it, the AIA exhibit bars an earthquake exclusion on the builder’s risk, so read the contract before you sign and agree any sub-limit there. The California Earthquake Authority is no help during construction: its policies are residential ones, for homeowners, condo owners, mobilehome owners and renters, sold through participating home insurers. Commercial earthquake insurance.
What to send me
- The address, whether it is in the City or the unincorporated county, and the fire protection district for a backcountry site.
- The contract’s insurance section and who carries the existing structure on a renovation.
- Completed value, with soft costs listed separately, and the lender’s insurance requirements.
- Schedule: first delivery, testing and startup, partial occupancy and completion.
- Site protection: the site safety plan, fire watch or temporary alarm, fencing and cameras.
- For renovations: the building’s current property declarations and who stays in the building during the work.
- For coastal sites: the coastal development permit and its special conditions.
Common questions
Who insures builder’s risk on large projects in San Diego County?
Owners and developers of apartment, commercial, custom-home and rebuild projects, and contractors who carry the policy under their contracts, send me the same file, and I take it to insurers that write construction in the county. Where fire is the sticking point in a very high zone, the California FAIR Plan is the fallback for that peril.
Does San Diego require a fire watch on a construction site?
In the City of San Diego, Fire-Rescue’s standard requires one during nonworking hours for new construction over 40 feet high or with more than 50,000 square feet per story, or when the fire code official requires it. A monitored temporary fire alarm can be proposed instead.
Does builder’s risk cover water damage during testing?
Building systems damaged during testing and startup are commonly covered, and the AIA’s insurance exhibit calls for it, but many policies carry a separate water or testing deductible and water mitigation conditions. Read both before you compare quotes.
Do I need builder’s risk to renovate an occupied apartment building?
If the building’s property policy excludes or limits coverage during the work, yes, and Fannie Mae requires it of its lenders in that case. Settle who insures the existing structure, because it is not always the builder’s risk.
Does the County’s 2026 wildfire code apply to my backcountry remodel?
The code applies to new buildings in fire hazard severity zones and excepts additions to and remodels of buildings first built before July 1, 2008 from its application rule. Your fire protection district confirms what applies to your project.
Is earthquake covered on builder’s risk in San Diego?
Not on most forms unless you add it. Look at the contract’s insurance exhibit before signing: the AIA version bars an earthquake exclusion unless the parties edit it.
General information about builder’s risk insurance for San Diego County construction as of November 2026, not legal advice. San Diego Fire-Rescue standards, the County Wildland-Urban Interface Code, coastal permit conditions, lender guides and contract forms change; confirm requirements with the City, the County or your fire protection district, and read your own contract and policy wording. Coverage depends on underwriting and the terms, conditions and exclusions of the policy actually issued.